New-Gene COVID-19 Antigen Detection Test Kit for Nasopharyngeal Swab/ Sputum
New-Gene COVID-19 Antigen Detection Test Kit for Nasopharyngeal Swab/ Sputum
New-Gene COVID-19 Antigen Detection Test Kit for Nasopharyngeal Swab/ Sputum
New-Gene COVID-19 Antigen Detection Test Kit for Nasopharyngeal Swab/ Sputum
New-Gene COVID-19 Antigen Detection Test Kit for Nasopharyngeal Swab/ Sputum
New-Gene COVID-19 Antigen Detection Test Kit for Nasopharyngeal Swab/ Sputum
New-Gene COVID-19 Antigen Detection Test Kit for Nasopharyngeal Swab/ Sputum
RM6.90RM162.50 Select options
Sale!

New-Gene COVID-19 Antigen Detection Test Kit for Nasopharyngeal Swab/ Sputum

RM6.90RM162.50

-67%

Easy to use: all reagents are ready to use (sputum collection material included)
Clinical sensitivity: 96.5%; Clinical specificity: 99.0%;
Rapid test: fast results available after 15 minutes;
Kit shelf life: 12 months;
Storage temperature: between 2°C and 30°C;
CE marking; KKM approved.

Clear

Please ensure understand our Policy before drop your order.

  • 05-07 days easy returns (depending on the products)
  • Drop your orders before 4.30pm for same day dispatch to delivery outlet.
  • 100% quality guarantee, the warranty is provided to every single product. Each defective product will be repaired or replaced within warranty period.
Guaranteed Safe Checkout

This product is suitable for the qualitative detection of novel coronavirus in nasopharyngeal swab or sputum samples. It provides an aid in the diagnosis of infection with novel coronavirus.

SUMMARY

The novel coronaviruses belong to the β genus. COVID-19 is an acute respiratory infectious disease. People are generally susceptible. Currently, the patients infected by the novel coronavirus are the main source of infection; asymptomatic virus carriers can also be infectious sources. Based on the current epidemiological investigation, the incubation period is 1 to 14 days, mostly 3 to 7 days. The main manifestations include fever, fatigue and dry cough. Nasal congestion, runny nose, sore throat, myalgia and diarrhea are also found in some cases.

COMPOSITION

  1. Test Card
  2. Sample Extraction Tube
  3. Tube Cap
  4. Sampling Swab
  5. Paper Cup
  6. Sputum Dropper

PRINCIPLE

The COVID-19 Antigen Detection Kit is an immunochromatographic membrane assay that uses highly sensitive monoclonal antibodies to detect nucleocapsid protein from SARS-CoV-2. The test strip is composed of the following parts: namely sample pad, reagent pad, reaction membrane, and absorbing pad. The reagent pad contains the colloidal-gold conjugated with the monoclonal antibody against the nucleocapsid protein of SARS-CoV-2; the reaction membrane contains the secondary antibodies for nucleocapsid protein of SARS-CoV-2. The whole strip is fixed inside a plastic device. When the sample is added into the sample well, conjugates absorbed in the reagent pad are dissolved and migrate along with the sample. If SARS-CoV-2 antigen is present in the sample, the complex of the anti-SARS-CoV-2 conjugate and the virus will be captured by the specific anti-SARS-CoV-2 monoclonal antibodies coated on the test line region (T). Absence of the T line suggests a negative result. To serve as a procedural control, a red line will always appear in the control line region (C) indicating that proper volume of sample has been added and membrane wicking effect has occurred.

STORAGE AND STABILITY

  1. Store the product package at temperature 2-30°C or 38-86°F, and avoid exposure to sunlight. The kit is stable within the expiration date printed on the labeling.
  2. Once an aluminum foil pouch is opened, the test card inside should be used within one hour. Prolonged exposure to hot and humid environment may cause inaccurate results.
  3. The lot number and the expiration date are printed on the labeling.

WARNINGS AND PRECAUTIONS

  1. Read the instructions for use carefully before using this product.
  2. This product is for professional use ONLY.
  3. This product is applicable to nasopharyngeal swab and sputum Using other sample types may cause inaccurate or invalid test results.
  4. Sputum rather than saliva is the type of sample recommended by WHO. Sputum comes from the respiratory tract while saliva comes from the mouth.
  5. If sputum samples cannot be obtained from patients, nasopharyngeal swab samples should be used for testing.
  6. Please make sure that a proper amount of sample is added for testing. Too much or too little sample amount may cause inaccurate results.
  7. If the test line or control line is out of the test window, do not use the test card. The test result is invalid and retest the sample with another one.
  8. This product is disposable. DO NOT recycle used components.
  9. Dispose of used products, samples, and other consumables as medical wastes under relevant regulations.

Additional information

Weight 0.215 kg
Dimensions 2 × 17 × 6.5 cm
OPTION

1 KIT, 25 KITS (ONE BOX)

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.